Model Number |
BW3F |
Model No.: BW3F Product Name: Multiparameter Patient Monitor Brief: â 6.4" color TFT LCD display â Attractive streamline outline design, portable, compact and lightweight â ST segment Analysis and Apnea Alarm function â Drug Dose Calculation and OXCRG Software â 72-hour tabular and graphic trends and data storage â High energy Li-ion battery for short-term transport and temporary power-down â Networking Capability
Products Information: Features â Attractive streamline outline design, portable, compact and lightweight â 6.4" color TFT LCD display â Operation menu with multi-language interface selection: English, Spanish, Portuguese, Chinese, French, German …… â Big Font Display â ST segment Analysis and Apnea Alarm function â Drug Dose Calculation and OXCRG Software â 72-hour tabular and graphic trends and data storage â High energy Li-ion battery for short-term transport and temporary power-down â Networking Capability. WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible â Linux Operation System â External display(VGA interface) â Dynamic Monitoring of blood pressure â Intelligent audio and visual alarm â Application: Adult, Pediatric and Neonate â Pacemaker detection and Arrhythmia Analysis( Optional) Technical Specs ECG Input: 5 lead ECG cable Lead section: lead âÂÂÂÂÂÂÂÂÂÂÂÂÂÂ
,âÂÂÂÂÂÂÂÂÂÂÂÂÂÂ
¡,âÂÂÂÂÂÂÂÂÂÂÂÂÂÂ
¢/ aVR, aVL, aVF/ V Gainï¼ÂÂÂÂÂÂÂÂÂÂÂÂÂÂmm/mVï¼ÂÂÂÂÂÂÂÂÂÂÂÂÂÂ: 1/4ï¼ÂÂÂÂÂÂÂÂÂÂÂÂÂÂ1/2ï¼ÂÂÂÂÂÂÂÂÂÂÂÂÂÂ1ï¼ÂÂÂÂÂÂÂÂÂÂÂÂÂÂ2ï¼ÂÂÂÂÂÂÂÂÂÂÂÂÂÂ4 Frequency response: Diagnosis 0.05 - 100Hz Monitor mode 0.5 - 40 Hz Surgery 1.0 - 25 Hz Sweep speed (mm/sec): 12.5, 25, 50 Heart rate range: 20-254 BPM ST segment deviation analysis: -0.8-+0.8mV Protection: Against electrosurgical interference and defibrillation NIBP Method: Automatic Oscillometric Measurement range: Systolic 4.0 - 37.0 kPa Diastolic 1.3 - 33.0 kPa Mean 2.6 - 35.0 kPa Scale: mmHg/Kpa Operating Mode: Manual/Auto/STAT Over pressure Protection: Yes SPO2 Measurement range: 0 - 100 % Pulse Rate range: 30- 254BPM Accuracy: ± 2 % Probe: For Neonate, pediatric, and adult Temperature Channel: Two Channels Measurement range: 29- 45â Accuracy: ±0.1â Scale: Celsius/Fahrenheit RESP. Method: Impedance Measurement range: 0 - 120 BPM Lead Connection: RA & LL or RA & RA Power requirements Input: 98ï½ÂÂÂÂÂÂÂÂÂÂÂÂÂÂ260 V AC, 50/60Hz Consumption: ≤ 80VA Safety standards: GB9706.1ã IEC 60601-1ãÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂUL 544 EtCO2( Optional) Method: Side Stream Measurement range: 0 % - 10.0 % in CO2 and et CO2ï¼Â Display: Waveform, Respiration Rate, EtCO2, FiCO2 Scale: mmHg/Kpa 2-IBP ( Optional) Channel: 2 Channels Parameter: SYS/DIA/MAP/Pulse Rate Scale: mmHg/kPa
|